Régulateur Dixell Pdf !new! May 2026
| Alarm Code | Meaning (French manual) | Likely Cause | |------------|------------------------|---------------| | E0 | Défaut sonde ambiante | Broken or shorted room probe | | E1 | Défaut sonde évaporateur | Broken defrost probe | | HA | Alarme haute température | Door left open, overload | | LA | Alarme basse température | Setpoint too low, faulty controller | | CA | Alarme externe (entrée numérique) | External alarm input activated | | dA | Dégivrage en cours | Normal info, not an error |
| Parameter | Function | Typical Value | |-----------|----------|----------------| | St | Setpoint | -18°C (freezer) / +3°C (cooler) | | dF | Defrost mode | ELE (electric), HtG (hot gas) | | MdF | Fan mode | C-n (run with compressor), on (continuous) | | Lt | Low temp alarm limit | -25°C | | Ht | High temp alarm limit | +10°C | | dtE | Defrost interval | 6 hours | | dtd | Max defrost duration | 30 minutes | régulateur dixell pdf
The official PDF for XR06C (French) includes a foldable parameter map on the last page — often printed by technicians. When a refrigeration system malfunctions, technicians refer to the PDF manual’s alarm table : | Alarm Code | Meaning (French manual) |